OIL ANALYSIS REPORTSFAX COPY
TO: WENDALL STRODERDFROM: James Feldhaus
TANK WIZARDS [TANPAL]WearCheck USA
1511 Masters Rd NW 501 Madison Ave.
PALM BAY, FLCary, NC
32907   USA27513    USA
(321)427-5149(919)379-4102
1(321)574-4131FAX (919)379-4050
wendall@tankwizards.com
 
Report Summary
Sample N°UnitWEARCONTAM'NFLUID
 WC-04123280 SUB BASE UNDER ER Diesel Fuel
NORMALNORMALMARGINAL
 
Total: 1 Sample Report(s)
 

The appearance of the Laboratory Accreditation Bureau ISO/IEC 17025 accreditation logo is meant to certify that WearCheck USA has met requirements for those parameters related to its accreditation.

The following pages contain sample report data via the methods listed on WearCheck USA’s Scope of Accreditation which is obtainable by searching for Certificate # L2367 at the following link: http://search.l-a-b.com/

 
*
Verify Your Contact Information Fax Back To (919)379-4050  
First Name WENDALL  
Last Name STRODERD  
Title  
Phone (321)427-5149  
Fax 1(321)574-4131  
Mobile Phone  
E-Mail wendall@tankwizards.com  
Company Name TANK WIZARDS  
Address 1511 MASTERS RD NW  
Address (con't)  
City PALM BAY  
State/Prov FL  
Zip/Postal Code 32907  
Country USA  
 
 
*
 
  
  IGNITION QUALITY FUEL ANALYSIS
FUEL CONDITION 
CONTAMINATION 
MARGINAL
NORMAL
 
SUB BASE UNDER ER - Diesel Fuel
Unit Make : SUB BASE
Unit Model : {n/a} Serial No : {n/a} Date Rec'd : Dec 13, 2016
Comp Make : {n/a} Cust. Ref No. : SB7000 Sample Date : Dec 12, 2016
Comp Model : {n/a} Stub No. : WC-04123280Diagnostician : Doug Bogart
RECOMMENDATION
Diagnostician: Doug Bogart
Fluid does not meet ASTM D975 requirements. Contact supplier.  
FUEL CONDITION
Gas Chromatogram [Fuel]
Distillation
Initial Boiling Point (°C)  170
90% recovered (°C)  328
Final Boiling Point (°C)  352
Ignition Quality
Cetane Number  49.9
API Gravity  38.2
Physcial Properties
Cloud Point (°C)  -9
Pour Point (°C)  
ClosedCup Flash Pt.(°C)  63
Sulfur Content (ppm)  17.0
Viscosity @40°C (cSt)  2.74
Color (ASTM)  L4.5
Comments
Sulfur value derived by ASTM D4294 method for ULSD validation. Sulfur level slightly above maximum allowed value for ULSD specification.
CONTAMINATION
There is no indication of any contamination in the component.
Water (%)  0.002
BS&W (%)  
Sugar  
Odor  
Bacteria  0
Yeast  0
Fungus  
Lead (ppm)  0.1
Nickel (ppm)  0.0
Aluminum(ppm)  0.0
Vanadium(ppm)  0.0
Silicon (ppm)  0.2
Biodiesel (%)  0.0
Gasoline (%)  0.0
ReportID:TANPAL-04123280 pg.1 of 2 (©2016-WearCheck)
*
If you have any questions concerning this sample report (work order no 04123280 ) please call 1-800-237-1369.
The leader in oil analysis

WearCheck International
Africa, Asia, Australia, Europe, North America
ATTN: WENDALL STRODERD
TANK WIZARDS
1511 MASTERS RD NW
PALM BAY, FL  32907
(321)427-5149
FAX (321)574-4131
Report ID - TANPAL [WUSCAR] 04123280 - Pg. 2 of 2
*