OIL ANALYSIS REPORTSFAX COPY
TO: Mike KirkFROM: Jeff Aiken
SALEM NATIONALEASE CORPORATION [SALWIN]
198 Park Plaza Drive
WINSTON SALEM, NC,
27105   USA   
(336)768-6896(919)379-4102
1(336)794-1594FAX 
mike.kirk@salemcorp.com
 
Report Summary
Sample N°UnitWEARCONTAM'NFLUID
 WC-M1375776 10448 Coolant
NORMALNORMALABNORMAL
 
Total: 1 Sample Report(s)
 

The appearance of the Laboratory Accreditation Bureau ISO/IEC 17025 accreditation logo is meant to certify that WearCheck USA has met requirements for those parameters related to its accreditation.

The following pages contain sample report data via the methods listed on WearCheck USA’s Scope of Accreditation which is obtainable by searching for Certificate # L2367 at the following link: //search.l-a-b.com/

 
*
Verify Your Contact Information Fax Back To  
First Name Mike  
Last Name Kirk  
Title  
Phone (336)768-6896  
Fax 1(336)794-1594  
Mobile Phone (336)918-5178  
E-Mail mike.kirk@salemcorp.com  
Company Name SALEM NATIONALEASE CORPORATION  
Address 198 PARK PLAZA DRIVE  
Address (con't)  
City WINSTON SALEM  
State/Prov NC  
Zip/Postal Code 27105  
Country USA  
 
 
*
 
  
  COOLANT ANALYSIS REPORT
CONDITION 
CONTAMINATION 
CORROSION 
ABNORMAL
NORMAL
NORMAL
 
10448 - Coolant
Unit Make : FREIGHTLINER
Unit Model : {n/a} Serial No : HLJD1779 Date Rec'd : Jul 11, 2017
Comp Make : CUMMINS Cust. Ref No. : {n/a}Sample Date : Jun 8, 2017
Comp Model : {n/a} Stub No. : WC-M1375776Diagnostician : Doug Bogart
RECOMMENDATION
 
We advise that you replenish the supplemental coolant additives (SCAs) and add per manufacturer`s recommendations.  
Sample Date     Current   UOM
Time on Unit     74801 mls
Time on Fluid     0 mls
Time on Fltr     0 mls
Fluid Maint.     n/a ---
Filter Maint.     n/a ---



CONDITION
 
Fluid: EXTENDED LIFE COOLANT
The nitrite level is lower than acceptable. The glycol level is acceptable. The pH level of this fluid is within the acceptable limits.  
Sample Date     Current   Base
Carboxylate     n/a ---
Nitrites (ppm)     448
pH     7.25
Glycol(%)     50
Freeze Point(°F)     -40




CONTAMINATION
 
There is no indication of any contamination in the component.  
Sample Date     Current   Abn
Appearance     normal ---
Visual Color     Red ---
TDS (ppm)     381.0 ---



CORROSION
 
 
Sample Date     Current   Abn
Iron     --- 15
Aluminum     --- 10
Copper     --- 10
Lead     --- 10
Tin     --- 10



ReportID:SALWIN-04259114 pg.1 of 2 (©2017-WearCheck)
*